中文名稱:人高鐵血紅蛋白(MHB)酶聯免疫試劑盒
-
貨號:CSB-E09493h
-
規(guī)格:96T/48T
-
價格:¥3600/¥2500
-
其他:
產品詳情
-
產品描述:人高鐵血紅蛋白(MHB)酶聯免疫試劑盒(CSB-E09493h)為雙抗夾心法ELISA試劑盒,定量檢測血清、血漿樣本中的MHB含量。試劑盒檢測范圍為0.47 μg/mL-30 μg/mL,高鐵血紅蛋白水平變化可為氧化應激相關機制研究提供參考。本產品適用于基礎醫(yī)學研究中探索溶血性貧血、藥物毒性反應、環(huán)境污染物暴露等場景下血紅蛋白氧化損傷的動態(tài)變化,也可用于體外實驗中評估化合物對紅細胞氧化還原狀態(tài)的影響,為氧化應激相關疾病機制研究及藥物開發(fā)中的毒性評估提供定量檢測工具。本品僅用于科研,不用于臨床診斷,產品具體參數及操作步驟詳見產品說明書。
-
縮寫:MHB
-
種屬:Homo sapiens (Human)
-
樣本類型:serum, plasma
-
檢測范圍:0.47 μg/mL-30 μg/mL
-
靈敏度:0.11 μg/mL
-
反應時間:1-5h
-
樣本體積:50-100ul
-
檢測波長:450 nm
-
研究領域:Others
-
測定原理:quantitative
-
測定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
線性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human MHB in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:100 Average % 86 Range % 80-91 1:200 Average % 87 Range % 83-93 1:400 Average % 90 Range % 87-93 1:800 Average % 95 Range % 91-103 -
回收率:
The recovery of human MHB spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 96 90-101 EDTA plasma (n=4) 88 82-96 -
標準曲線:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. µg/ml OD1 OD2 Average Corrected 30 2.281 2.113 2.197 2.095 15 1.913 1.851 1.882 1.780 7.5 1.596 1.516 1.556 1.454 3.75 1.099 1.097 1.098 0.996 1.88 0.567 0.526 0.547 0.445 0.94 0.312 0.304 0.308 0.206 0.47 0.208 0.201 0.205 0.103 0 0.104 0.100 0.102 -
數據處理:
-
貨期:3-5 working days
引用文獻
- The Effect of Nitrate-Contaminated Drinking Water and Vegetables on the Prevalence of Acquired Methemoglobinemia in Beit Lahia City in Palestine J Shaban,Water,2023
- Eccentric Cycling Training Improves Erythrocyte Antioxidant and Oxygen Releasing Capacity Associated with Enhanced Anaerobic Glycolysis and Intracellular Acidosis YC Huang,Antioxidants,2021
- Fatal methemoglobinemia due to acute inhalation of methyl nitrite in an industrial accident Huang S,J Forensic Sci,2020
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-