中文名稱:豬中性粒細胞明膠酶相關脂質運載蛋白(NGAL)酶聯(lián)免疫試劑盒
-
貨號:CSB-E16507p
-
規(guī)格:96T/48T
-
價格:¥3800/¥2500
-
其他:
產(chǎn)品詳情
-
產(chǎn)品描述:豬中性粒細胞明膠酶相關脂質運載蛋白(NGAL)酶聯(lián)免疫試劑盒(CSB-E16507p)為競爭法ELISA試劑盒,定量檢測血清、血漿、組織勻漿樣本中的NGAL含量。試劑盒檢測范圍為7.8 pg/mL-500 pg/mL,可廣泛應用于豬模型中的炎癥應答機制研究、腎功能損傷評估及藥物干預效果分析等領域,能為獸醫(yī)病理學、畜牧科學及比較醫(yī)學領域的科研工作者提供可靠工具,助力于動物疾病模型的建立與新型治療策略開發(fā)。本品僅用于科研,不用于臨床診斷,產(chǎn)品具體參數(shù)及操作步驟詳見產(chǎn)品說明書。
-
縮寫:NGAL
-
Uniprot No.:
-
種屬:Sus scrofa (Pig)
-
樣本類型:serum, plasma, tissue homogenates
-
檢測范圍:7.8 pg/mL-500 pg/mL
-
靈敏度:1.95 pg/mL
-
反應時間:1-5h
-
樣本體積:50-100ul
-
檢測波長:450 nm
-
研究領域:Metabolism
-
測定原理:quantitative
-
測定方法:Competitive
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
線性度:
To assess the linearity of the assay, samples were spiked with high concentrations of pig NGAL in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:200 Average % 105 Range % 101-108 1:400 Average % 96 Range % 92-98 1:800 Average % 96 Range % 90-99 1:1600 Average % 89 Range % 84-93 -
回收率:
The recovery of pig NGAL spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 91 87-94 EDTA plasma (n=4) 99 99-103 -
標準曲線:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. pg/ml OD1 OD2 Average 500 0.132 0.135 0.134 250 0.254 0.265 0.260 125 0.612 0.563 0.588 62.5 1.054 1.068 1.061 31.2 1.538 1.652 1.595 15.6 2.079 2.122 2.101 7.8 2.435 2.454 2.445 0 2.841 2.878 2.860 -
數(shù)據(jù)處理:
-
貨期:3-5 working days
引用文獻
- Renal hemodynamics by return cannular position of extracorporeal membrane oxygenation in swine Kim H J, et al,Journal of Thoracic Disease,2019
- Physiological effects of altering oxygenation during kidney normothermic machine perfusion Adams TD, et al,American Journal Of Physiology-Renal Physiology,2019
相關問答
■ 常見問題解答
Q:
I would like to be sure it is good both for urine and serum. Could you confirm?
A:
Thanks for your inquiry. We tested serum and plasma samples under 1:500 dilution before and the test value is 30--125pg/ml with this kit CSB-E16507p.
The final concentration is 15--62.5ng/ml. We suggest you order 24T sample kit and do a pretest first if you want to test urine samples. Pls let me know if you have any further questions. Thank you.
The final concentration is 15--62.5ng/ml. We suggest you order 24T sample kit and do a pretest first if you want to test urine samples. Pls let me know if you have any further questions. Thank you.
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-