Mouse Angiotensin 1-7(Ang1-7)ELISA Kit
-
中文名稱(chēng):小鼠血管緊張素1-7(Ang1-7)酶聯(lián)免疫試劑盒
-
貨號(hào):CSB-E13763m
-
規(guī)格:96T/48T
-
價(jià)格:¥3600/¥2500
-
其他:
產(chǎn)品詳情
-
產(chǎn)品描述:小鼠血管緊張素1-7(Ang1-7)酶聯(lián)免疫試劑盒(CSB-E13763m)為雙抗夾心法ELISA試劑盒,定量檢測(cè)血清、血漿、組織培養(yǎng)上清液、組織勻漿樣本中的Ang1-7含量。Ang1-7是有研究?jī)r(jià)值的靶點(diǎn)。它在心血管、腎臟等多個(gè)系統(tǒng)發(fā)揮作用,具有舒張血管、抗增殖、抗炎等效應(yīng)。研究機(jī)制方面,主要通過(guò)與Mas受體結(jié)合,激活下游信號(hào)通路,調(diào)節(jié)細(xì)胞功能,改善器官病理生理狀態(tài)。試劑盒檢測(cè)范圍為6.25 pg/mL-400 pg/mL,適用于實(shí)驗(yàn)室對(duì)小鼠疾病模型中Ang1-7的動(dòng)態(tài)監(jiān)測(cè),如高血壓、心肌肥厚、腎臟損傷等研究的生物標(biāo)志物分析,或體外藥物篩選實(shí)驗(yàn)中細(xì)胞因子分泌水平的定量評(píng)估。Ang1-7水平變化常被用于心血管疾病模型研究、代謝綜合征機(jī)制探索及藥物干預(yù)效果評(píng)估。本品僅用于科研,不用于臨床診斷,產(chǎn)品具體參數(shù)及操作步驟詳見(jiàn)產(chǎn)品說(shuō)明書(shū)。
-
縮寫(xiě):Ang1-7
-
種屬:Mus musculus (Mouse)
-
樣本類(lèi)型:serum, plasma, cell culture supernates, tissue homogenates
-
檢測(cè)范圍:6.25 pg/mL-400 pg/mL
-
靈敏度:1.56 pg/mL
-
反應(yīng)時(shí)間:1-5h
-
樣本體積:50-100ul
-
檢測(cè)波長(zhǎng):450 nm
-
研究領(lǐng)域:Cardiovascular
-
測(cè)定原理:quantitative
-
測(cè)定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
線(xiàn)性度:
To assess the linearity of the assay, samples were spiked with high concentrations of mouse Ang1-7 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:1 Average % 91 Range % 86-95 1:2 Average % 93 Range % 87-99 1:4 Average % 95 Range % 89-102 1:8 Average % 95 Range % 87-98 -
回收率:
The recovery of mouse Ang1-7 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 96 92-98 EDTA plasma (n=4) 95 91-98 -
標(biāo)準(zhǔn)曲線(xiàn):
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. pg/ml OD1 OD2 Average Corrected 400 2.745 2.721 2.733 2.597 200 2.316 2.245 2.281 2.145 100 1.923 1.898 1.911 1.775 50 1.467 1.366 1.417 1.281 25 0.796 0.788 0.792 0.656 12.5 0.458 0.447 0.453 0.317 6.25 0.258 0.242 0.250 0.114 0 0.138 0.134 0.136 -
數(shù)據(jù)處理:
-
貨期:3-5 working days
引用文獻(xiàn)
- Activation of central Angiotensin-(1-7)/Mas receptor alleviates synaptic damage in diabetes-associated cognitive impairment via modulating AKT/FOXO1/PACAP axis S Tian, T Wu, Z Zhang, S Lv, X Ji,International Journal of Biological Sciences,2025
- Human placental mesenchymal stem cells transplantation repairs the alveolar epithelial barrier to alleviate lipopolysaccharides-induced acute lung injury W Yu, Y Lv, R Xuan, P Han, H Xu, X Ma,Biochemical Pharmacology,2024
- A53T α-synuclein mutation increases susceptibility to postoperative delayed neurocognitive recovery via hippocampal Ang-(1–7)/MasR axis J Hong,Biochemical pharmacology,2024
- Mas receptor activation facilitates innate hematoma resolution and neurological recovery after hemorrhagic stroke in mice X Deng,Journal of neuroinflammation,2024
- Potential therapeutic implications of calcitriol administration and weight reduction on CD4 T cell dysregulation and renin angiotensin system-associated acute lung injury in septic obese mice CL Yeh,Biomedicine & pharmacotherapy,2023
- ApoE4 associated with severe COVID-19 outcomes via downregulation of ACE2 and imbalanced RAS pathway F Chen,Journal of translational medicine,2023
- Recombinant human angiotensin-converting enzyme 2 plays a protective role in mice with sepsis-induced cardiac dysfunction through multiple signaling pathways dependent on converting angiotensin II to angiotensin 1–7 C Wu,Annals of Translational Medicine,2023
- Renal angiotensin I-converting enzyme-deficient mice are protected against aristolochic acid nephropathy A Juretzko,Pflugers Archiv,2022
- Imatinib and methazolamide ameliorate COVID-19-induced metabolic complications via elevating ACE2 enzymatic activity and inhibiting viral entry Zilun L,Cell Metabolism,2022
- ACE2-like carboxypeptidase B38-CAP protects from SARS-CoV-2-induced lung injury Tomokazu Yamaguchi,nature communications,2021
- Ambient fine particulate matter induced the elevation of blood pressure through ACE2/Ang(1–7) pathway: The evidence from urine metabolites X Du,Ecotoxicology and Environmental Safety,2020
- B38-CAP is a bacteria-derived ACE2-like enzyme that suppresses hypertension and cardiac dysfunction T Minato,Nature Communications,2020
- Ginsenoside Rg3 Attenuates Angiotensin II-Mediated Renal Injury in Rats and Mice by Upregulating Angiotensin-Converting Enzyme 2 in the Renal Tissue Liu H, et al,Evidence-Based Complementary and Alternative Medicine,2019
- Effects of exendin-4 on the intrarenal renin-angiotensin system and interstitial fibrosis in unilateral ureteral obstruction mice: Exendin-4 and unilateral ureteral obstruction Ying Le.et al,SAGE Journals,2016
- The effects of different angiotensin II type 1 receptor blockers on the regulation of the ACE-AngII-AT1 and ACE2-Ang(1-7)-Mas axes in pressure overload-induced cardiac remodeling in male mice. Wang X.et al,J Mol Cell Cardiol.,2016
- Control of Adipogenesis by the Autocrine Interplays between Angiotensin (1-7)/Mas receptor and Angiotensin II/AT1 receptor Signaling Pathways Than A et al,J Biol Chem,2013
相關(guān)產(chǎn)品
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-