搡老女人多毛老妇女中国,日韩亚洲欧美中文高清在线,人妻少妇一区二区三区,色妞色综合久久夜夜,日本熟妇xxxx

Your Good Partner in Biology Research

Pig Syndecan-1/CD138(SDC1) ELISA Kit

  • 中文名稱:
    豬Syndecan-1/CD138(SDC1)酶聯(lián)免疫試劑盒
  • 貨號:
    CSB-E17413p
  • 規(guī)格:
    96T/48T
  • 價格:
    ¥3800/¥2500
  • 其他:

產(chǎn)品詳情

  • 產(chǎn)品描述:
    豬Syndecan-1/CD138(SDC1)酶聯(lián)免疫試劑盒(CSB-E17413p)為雙抗夾心法ELISA試劑盒,定量檢測血清、血漿、組織勻漿樣本中的SDC1含量。豬Syndecan-1(CD138)是一種細胞表面硫酸乙酰肝素蛋白聚糖,參與細胞增殖、遷移和細胞基質(zhì)相互作用。其表達異常與多種疾病相關(guān),如癌癥和炎癥性疾病,研究其機制有助于開發(fā)新的治療策略。試劑盒檢測范圍為5 ng/mL-320 ng/mL,該產(chǎn)品可應(yīng)用于豬模型研究中SDC1蛋白的表達分析,如評估炎癥性疾病進程、組織再生機制研究或作為特定病理狀態(tài)的潛在生物標(biāo)志物探索,僅限科研用途。本品僅用于科研,不用于臨床診斷,產(chǎn)品具體參數(shù)及操作步驟詳見產(chǎn)品說明書。
  • 縮寫:
  • Uniprot No.:
  • 種屬:
    Sus scrofa (Pig)
  • 樣本類型:
    serum, plasma, tissue homogenates
  • 檢測范圍:
    5 ng/mL-320 ng/mL
  • 靈敏度:
    1.25 ng/mL
  • 反應(yīng)時間:
    1-5h
  • 樣本體積:
    50-100ul
  • 檢測波長:
    450 nm
  • 研究領(lǐng)域:
    Signal Transduction
  • 測定原理:
    quantitative
  • 測定方法:
    Sandwich
  • 精密度:
    Intra-assay Precision (Precision within an assay): CV%<8%
    Three samples of known concentration were tested twenty times on one plate to assess.
    Inter-assay Precision (Precision between assays): CV%<10%
    Three samples of known concentration were tested in twenty assays to assess.
  • 線性度:
    To assess the linearity of the assay, samples were spiked with high concentrations of pig SDC1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
     SampleSerum(n=4)
    1:1Average %85
    Range %80-90
    1:2Average %93
    Range %87-102
    1:4Average %97
    Range %92-102
    1:8Average %91
    Range %80-98
  • 回收率:
    The recovery of pig SDC1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
    Sample TypeAverage % RecoveryRange
    Serum (n=5) 9381-98
    EDTA plasma (n=4)9890-105
  • 標(biāo)準(zhǔn)曲線:
    These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
    ng/mlOD1OD2AverageCorrected
    3202.413 2.395 2.404 2.094
    1602.114 2.004 2.059 1.749
    801.762 1.674 1.718 1.408
    401.434 1.339 1.387 1.077
    201.002 0.953 0.978 0.668
    100.866 0.859 0.863 0.553
    50.535 0.529 0.532 0.222
    00.322 0.297 0.310  
  • 數(shù)據(jù)處理:
  • 貨期:
    3-5 working days

產(chǎn)品評價

相關(guān)問答

 常見問題解答
Q:

Good morning, I am wondering if you could let me know what the minimum sample volume required for testing is?

A:
Thanks for your inquiry!
CSB-E17413p
The sample volume needed for single well is 100ul. If your sample volume is not enough, then it may lead to false negative. So we suggest you prepare enough sample.
Q:

Is there usually a better signal in serum samples or perfusate samples
taken while on EVLP?

A:
Thanks for your inquiry!
CSB-E17413p
Usually we use this kit to test serum and plasma samples. Regarding perfusate samples on EVLP before,we can not ensure 100%. In theory if the concentration is within the detection range of the kit, it can be detected out. We suggest you do a pretest first.